MongoDBCVE-2026-81518

MongoDB BI Connector: improper certificate validation

MongoDB

CVE-2026-81518 · Published Aug 28, 2026 · updated Sep 29, 2026

High8.7
Fix: upgrade to 2.14.31 or later
MongoDB advisory

When mongosqld is configured with a client certificate authority file, the listener requests a client certificate during the TLS handshake but does not require one, so a client that presents no certificate is still accepted. In deployments that rely on client certificates as the sole means of identifying users, a remote party with network access to the listener can therefore establish a session and read the MongoDB data exposed through the connector.

Affected versions

PackageAffectedFixed in
BI Connector
Product
< 2.14.312.14.31
Details and references
CVSS 4.0
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Severity from
the vendor (its own CVE record or advisory)
Weakness
CWE-295