AI and data stack advisories

Severe, 6 weeks1496Projects326

1496 severe, 6 weeks · 326 projects

National InstrumentsCVE-2026-18444

National Instruments LabVIEW: out-of-bounds read

National Instruments

CVE-2026-18444 · Published Aug 25, 2026 · updated Nov 3, 2026

Medium6.9
Fix: upgrade to 23.0.0 or later (4 fixed versions below)
National Instruments advisory

There is an integer conversion vulnerability resulting in an out-of-bounds read when loading images recently discovered in NI LabVIEW.  This may result in information disclosure or arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI file.  This vulnerability affects NI LabVIEW 2026 Q3 and prior versions.

Affected versions

PackageAffectedFixed in
LabVIEW
Product
< 23.0.023.0.0
>= 23.1.0, < 23.3.1023.3.10
>= 24.1.0, < 24.3.724.3.7
>= 25.1.0, < 25.3.525.3.5
Details and references
CVSS 4.0
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Severity from
the vendor (its own CVE record or advisory)
Weakness
CWE-195

More National Instruments advisories