SiemensCVE-2026-112136

Siemens Mendix Studio Pro: attacker could interact with the MCP Server remotely

Siemens

CVE-2026-112136 · Published Nov 10, 2026 · updated Nov 12, 2026

Critical9.2
Fix: upgrade to V11.16.0 or later (2 fixed versions below)
Siemens advisory

A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.

Affected versions

PackageAffectedFixed in
Mendix Studio Pro 11
Product
>= V11.15.0, < V11.16.0V11.16.0
Mendix Studio Pro 11.12
Product
>= V11.12.6, < V11.12.7V11.12.7
Details and references
CVSS 4.0
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X